Parameter
Pr. No. Name
Stall prevention ope-
165
ration level for restart
High-speed setting
271
maximum current
Middle-speed setting
272
minimum current
279
Brake opening current
Current average value
557
monitor signal output
reference current
Energy saving moni-
893
tor reference (motor
capacity)
Tab. 6-34:
Influence of Pr. 570 on other parameters (2)
The rated current differs according to the inverter capacity.
NOTE
When Pr. 570 = "0 or 1", Pr. 260 "PWM frequency automatic switchover" becomes valid.
(Refer to section 6.19.1.)
Precautions for the FR-A740-01800 or less and FR-A740-02160 or more
If Pr. 570 is set to "0 (SLD) or 1 (LD)" when using FR-A740-01800, specifications of the inverter
change to that of the FR-A740-02160. Setting change of Pr. 570 is made valid after all parameter
clear and inverter reset.
Inverter
FR-A740-01800
FR-A740-02160
Tab. 6-35: Influence of Pr. 570 on the inverter specifications
Example
For example, when using the FR-A740-01800, setting "0" in Pr. 570 and performing inverter
reset after all parameter clear will change the setting range of Pr. 9 from "0 to 500A" to "0 to
3600A" and the minimum setting increments from "0.01A" to "0.1A". (Refer to the parameter
list for other parameters.)
FR-A700 EC
0
Setting Range
0–120%
Initial Value
110%
Setting Range
0–120%
Initial Value
50%
Setting Range
0–120%
Initial Value
100%
Setting Range
0–220%
Initial Value
130%
SLD rated
Initial Value
current
SLD value of
Initial Value
applied motor
capacity
Multiple Rating
Setting
SLD
LD
ND
HD
SLD
LD
ND
HD
Adjust the output torque of the motor (current)
Pr. 570
1
(initial value)
0–150%
120%
0–150%
50%
0–150%
100%
0–220%
130%
LD rated
current
LD value of
applied motor
applied motor
capacity
Parameter Setting
The inverter operates in the same manner as the FR-A740-02160 or
more.
Parameter setting range, minimum setting increments, initial values,
etc. change to those of the 02160 or more. Refer to the parameter list
for parameters whose values change.
No change
No change
2
3
0–220%
0–280%
150%
200%
0–220%
0–280%
50%
50%
0–220%
0–280%
100%
100%
0–220%
0–280%
130%
130%
ND rated
HD rated
current
current
ND value of
HD value of
applied motor
capacity
capacity
Refer
to
Page
6-337
6-509
6-509
6-261
6-532
6-360
6 - 167