Frequency/torque setting by analog input (terminals 1, 2 and 4)
Perform operation by analog input current
When the pressure or temperature is controlled constant by a fan, pump, etc., automatic oper-
ation can be performed by inputting the output signal 0/4 to 20mA of the adjuster to across the
terminals 4-5.
The AU signal must be turned on to use the terminal 4.
Setting any of "6, 7, 16, 17" in Pr. 73 changes the terminal 2 to the current input specification.
At this time, the AU signal need not be turned on.
Perform forward/reverse rotation by analog input (polarity reversible operation)
Setting any of "10 to 17" in Pr. 73 enables polarity reversible operation.
Providing ± input (0 to ±5V or 0 to ±10V) to the terminal 1 enables forward/reverse rotation
operation according to the polarity.
Reversible
Not reversible
6 - 376
Forward rotation
0/4 to 20mA DC
Current
Frequency
input
setting
equipment
Connection diagram
using terminal 4 (0/4 to 20mA DC)
Set frequency
[Hz]
Reverse
rotation
Terminal 1 input
Fig. 6-178:
Frequency setting by the function "Current
input 0/4 to 20mA" assigned to terminal 4
Fig. 6-179:
Compensation input characteristic when STF
Forward
is on
rotation
Parameter
I001184E