Wiring
FR-A740-00170 to 00250-EC
Loosen the upper screws
Remove the jumpers
Connect the separate power supply cable for the control circuit to the upper terminals
R1/L11 and S1/L21.
Fig. 3-10: Detailed view of the terminals
FR-A740-00310 to 12120-EC
Loosen the upper screws
Remove the jumpers
Connect the separate power supply cable for the control circuit to the upper terminals
R1/L11 and S1/L21.
Fig. 3-11: Detailed view of the terminals
b
CAUTION:
Never connect the power cable to the terminals in the lower stand. Doing so will
damage the inverter.
FR-A700 EC
and then the lower screws
.
Main circuit terminals
and then the lower screws
.
Power supply terminal block
for the control circuit
Main power supply
Main circuit connection
.
.
Power supply terminal block
for the control circuit
I001025E
I001026E