Parameter overview
Parameter
Func-
Name
tion
STF terminal function
178
selection
STR terminal function
179
selection
RL terminal function
180
selection
RM terminal function
181
selection
RH terminal function
182
selection
RT terminal function
183
selection
AU terminal function
184
selection
JOG terminal function
185
selection
CS terminal function
186
selection
MRS terminal function
187
selection
STOP terminal function
188
selection
RES terminal function
189
selection
Tab. 6-1:
Parameter overview (36)
6 - 36
Incre-
Initial
Setting
ments
Value
Range
0–20/
22–28/37/
1
60
42–44/50/
60/62/
64–71/9999
0–20/
22–28/37/
1
61
42–44/50/
61/62/
64–71/9999
1
0
1
1
0–20/
22–28/37/
42–44/50/
62/64–71/
9999
1
2
1
3
0–20/
22–28/37/
1
4
42–44/50/
62–71/9999
1
5
1
6
1
24
1
25
0–20/
22–28/37
42–44/50/
62/64–71/
9999
1
62
Description
0: Low-speed operation
command
1: Middle-speed operation
command
2: High-speed operation
command
3: Second function selection
4: Terminal 4 input selection
5: Jog operation selection
6: Selection of automatic restart
after instantaneous power
failure
7: External thermal relay input
8: Fifteen speed selection
9: Third function
10: Inverter operation enable
signal (FR-HC, MT-HC, FR-CV
connection)
11: FR-HC, MT-HC connection,
instantaneous power failure
detection
12: PU operation external interlock
13: External DC injection brake start
14: PID control valid terminal
15: Brake opening completion
signal
16: PU-external operation switch-
over
17: Load pattern selection
forward/reverse rotation boost
18: V/f switch over
19: Load torque high-speed
frequency
20: S-pattern acceleration/decel-
eration C switching terminal
22: Orientation command
23: Pre-excitation
24: Output stop
25: Start self-holding selection
26: Control mode changing
27: Torque limit selection
28: Start time tuning
37: Traverse function selection
42: Torque bias selection 1 *
43: Torque bias selection 2 *
44: P/PI control switchover
50: Sequence start
60: Forward rotation command
(assigned to STF terminal
(Pr. 178) only)
61: Reverse rotation command
(assigned to STR terminal
(Pr. 179) only)
62: Inverter reset
63: PTC thermistor input (assigned
to AU terminal (Pr. 184) only)
64: PID forward/reverse action
switchover
65: NET/PU operation switchover
66: External/NET operation
switchover
67: Command source switchover
68: Conditional position pulse
train sign *
69: Conditional position droop
pulse clear *
70: DC feeding operation permission
71: DC feeding cancel
9999: No function
*
Available only when used with
the FR-A7AP
Parameter
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-286

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a740 ecFr-a700 ec

Table of Contents