Mean Time (GMT). This may not be the time zone in which the switch is located. Use the
clock timezone command to configure a time zone specifying the number of hours and
optionally the number of minutes difference from UTC. To set the switch clock to UTC, use
the no form of the command.
Format
clock timezone zone-name +/-hours-offset [+/-minutes-offset]
Mode
Global Config
Default
no clock timezone
Term
Definition
zone-name
A name to associate with the time zone
hours-offset
Number of hours difference with UTC
minutes-offset
Number of minutes difference with UTC
no clock timezone
This command sets the switch to UTC time.
Format
no clock timezone
Mode
Global Config
clock set
This command sets the system time and date.
Format
clock set <hh:mm:ss>
clock set <mm/dd/yyyy>
Mode
Global Config
clock summer-time recurring
Use the clock summer-time recurring command to set the summertime offset to UTC
recursively every year. If the optional parameters are not specified, they are read as either '0'
or '\0', as appropriate.
Use the following parameters to configure the summer-time.
•
USA—the US Daylight saving time setting is used (Start --- March, 2nd sunday 02:00 AM,
End --- Nov, 1st sunday, 2:00 AM)
•
EU—the European Union Daylight savings time is used (Start --- March, 5th Sunday
02:00 AM, End --- October, 5th Sunday, 3:00 AM)
•
week—Week of the month. (Range: 1-5, first, last)
•
day—Day of the week. (Range: The first three letters by name; sun, for example.)
•
month—Month. (Range: The first three letters by name; jan, for example.)
ProSafe Managed Switch
Utility Commands
553