NETGEAR ProSafe M7100-24X User Manual page 521

Prosafe managed switch
Hide thumbs Also See for ProSafe M7100-24X:
Table of Contents

Advertisement

Term
Definition
Unicast Packets
The number of subnetwork-unicast packets delivered to a higher-layer protocol.
Received
Multicast Packets
The total number of packets received that were directed to a multicast address. Note that this
Received
number does not include packets directed to the broadcast address.
Broadcast
The total number of packets received that were directed to the broadcast address. Note that
Packets Received
this does not include multicast packets.
Receive Packets
The number of inbound packets which were chosen to be discarded even though no errors had
Discarded
been detected to prevent their being deliverable to a higher-layer protocol. A possible reason
for discarding a packet could be to free up buffer space.
Octets
The total number of octets transmitted out of the interface, including framing characters.
Transmitted
Packets
The total number of packets transmitted out of the interface.
Transmitted
without Errors
Unicast Packets
The total number of packets that higher-level protocols requested be transmitted to a
Transmitted
subnetwork-unicast address, including those that were discarded or not sent.
Multicast Packets
The total number of packets that higher-level protocols requested be transmitted to a Multicast
Transmitted
address, including those that were discarded or not sent.
Broadcast
The total number of packets that higher-level protocols requested be transmitted to the
Packets
Broadcast address, including those that were discarded or not sent.
Transmitted
Most Address
The highest number of Forwarding Database Address Table entries that have been learned by
Entries Ever Used
this switch since the most recent reboot.
Address Entries
The number of Learned and static entries in the Forwarding Database Address Table for this
in Use
switch.
Maximum VLAN
The maximum number of Virtual LANs (VLANs) allowed on this switch.
Entries
Most VLAN
The largest number of VLANs that have been active on this switch since the last reboot.
Entries Ever Used
Static VLAN
The number of presently active VLAN entries on this switch that have been created statically.
Entries
Dynamic VLAN
The number of presently active VLAN entries on this switch that have been created by GVRP
Entries
registration.
VLAN Deletes
The number of VLANs on this switch that have been created and then deleted since the last
reboot.
Time Since
The elapsed time, in days, hours, minutes, and seconds, since the statistics for this switch were
Counters Last
last cleared.
Cleared
ProSafe Managed Switch
Utility Commands
521

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents