Udld Message Time; Udld Timeout Interval - NETGEAR ProSafe M7100-24X User Manual

Prosafe managed switch
Hide thumbs Also See for ProSafe M7100-24X:
Table of Contents

Advertisement

no udld enable
This command disables udld globally on the switch.
Format
no udld enable
Mode
Global Config

udld message time

This command configures the interval between UDLD probe messages on ports that are in
the advertisement phase. The range is from 7 to 90 seconds.
Default
15
Format
udld message time <interval>
Mode
Global Config

udld timeout interval

This command configures the time interval after which UDLD link is considered to be
unidirectional. The range is from 5 to 60 seconds.
Default
5
Format
udld timeout interval <interval>
Mode
Global Config
udld enable
This command enables UDLD on the specified interface.
Default
disabled
Format
udld enable
Mode
Interface Config
no udld enable
This command disables udld on the specified interface.
Format
no udld enable
Mode
Interface Config