unconfig flowstats ports

unconfig flowstats {filter <filter#> ports <portlist>} {ports [<portlist> |
all]}
Description
Resets the flow statistics configuration parameters for the specified ports to their default values.
Syntax Description
filter#
portlist
Default
N/A.
Usage Guidelines
This command does not affect the enabled or disabled status of flow collection on these ports, nor does
it affect the configured export destinations.
Example
The following command resets the flow statistics configuration parameters for port 1 of slot 8 to their
default values:
unconfig flowstats ports 8:1
History
This command was first available in ExtremeWare 6.1.5b20 for the PoS module
This command was made available in ExtremeWare 6.2 for all "i" series platforms.
Platform Availability
This command is available on the "i" series platforms.
ExtremeWare Software 7.0.0 Command Reference Guide
Specifies the filter specification that should be removed.
Specifies a set of ports or slots and ports that should be reset. May be in the
form 1, 2, 3-5, 2:5, 2:6-2:8.
unconfig flowstats ports