Specifies the interval at which I/O information is to be displayed, in
the range from 1 to 60 (seconds). When this parameter is omitted,
the default (3 seconds) is applied.
-count count
Specifies the number of times I/O information is to be displayed, in
the range from 1 to 999. When this parameter is omitted, the default
(10) is applied.
-t
Omits the title for each information item.
Table 6-22 Items displayed as I/O information for each HBA port
Item
HBA port ID
HbaID
Port (host port number in hexadecimal) and Bus (bus number
Port.Bus
in hexadecimal) separated by a period
HBA port configuration information. The names of the physical
Physical
device files under the /devices directory are displayed.
Device
Date and time in which the command began executing, in the
StartTime
format yyyy/mm/dd hh:mm:ss
Time elapsed since command execution began, in the format
ElapsedTime
hh:mm:ss
Total I/O count for the displayed paths during a specified
IO-Count
interval indicated by a whole number (indicated by a decimal
number). The maximum value that can be displayed is 2
(4294967295). If the total I/O count reaches the maximum
value, it is reset, and the count is re-started from 0.
Total I/O error count for the displayed paths during a specified
IO-Errors
interval, indicated by a whole number (indicated by a decimal
number). The maximum value that can be displayed is 2
(4294967295). If the total I/O error count reaches the
maximum value, it is reset, and the count is re-started from 0.
Example
# /opt/DynamicLinkManager/bin/dlnkmgr monitor -hbaid 0 -intvl
30 -count 3
HbaID
Port.Bus
Physical Device : /devices/pci@8,70000/JNI,FCE@2
StartTime
ElapsedTime IO-Count
00:00:30
00:01:00
00:01:30
KAPL01001-I The HDLM command completed normally. Operation
name = monitor, completion time = yyyy/mm/dd hh:mm:ss
Command Reference
Hitachi Dynamic Link Manager User Guide (for Solaris(R))
Description
: 00000
: 0001.0000
: yyyy/mm/dd hh:mm:ss
IO-Errors
223
10
1140
1
557
0
32
- 1
32
- 1
6-65