Status
Type
6-46
Displayed Item
No
Summary
displayed
This number combined with the storage system name
(shown in DskName) identifies the LU that is accessed by a
path.
Port number of the CHA, which identifies the CHA port that
#
CP
is mounted on the storage system.
You can identify an actual CHA port by referencing this
number from the storage system management program.
Status of the path
Paths that are Offline(E) or Online(E) require corrective
action. Take appropriate action by referring to
for a Path Error on page
#
Attribute of the path
Type
Command Reference
Hitachi Dynamic Link Manager User Guide (for Solaris(R))
Description
For the Lightning 9900 Series, Lightning 9900V Series,
Hitachi NSC55, Hitachi Universal Storage Platform 100,
Hitachi Universal Storage Platform 600, or Hitachi
Universal Storage Platform 1100, indicated by a
hexadecimal number. The first two characters of iLU
are the CU number, and the last two characters are the
internal LU number within the CU.
For HP XP10000/HP XP12000, P9500, or SVS, indicated
by a hexadecimal number. The first three characters of
iLU are the CU number, and the last two characters are
the internal LU number within the CU. The first
character of the CU number is the value 0.
For the Thunder 9500V Series, or Hitachi AMS2000/
AMS/WMS/SMS series, indicated by a decimal number.
The entire value of iLU is the internal LU number within
the storage system. You can identify an actual LU by
referencing iLU from the storage system management
program.
For Universal Storage Platform V/VM, or Hitachi Virtual
Storage Platform, indicated by a hexadecimal number.
The first two characters of iLU are the number of the
logical DKC (Disk Controller), the middle two numbers
are the CU number, and the last two characters are the
internal LU number within the CU.
Online: Online
Offline(C): Placed offline by using a command
Offline(E): Offline due to an error
Online(E): Failure has occurred (If none of the paths
accessing one LU have an Online status, one of those
paths is changed to the Online(E) status.)
5-3.
Own: Owner path
Non: Non-owner path