Inbound Phonebook - Multitech MULTIVOIP MVP-2410 User Manual

Voice over ip gateways
Hide thumbs Also See for MULTIVOIP MVP-2410:
Table of Contents

Advertisement

MultiVOIP User Guide
field in the Outbound Phonebook. This precludes the problem of having to
make two inbound phonebook entries at remote voips, one to account for
situations where "8" is used as the PBX access digit, and another for when
"9" is used.
8. Select the voip protocol that you will use (H.323, SIP, or SPP).
9. Click OK to exit from the Add/Edit Outbound Phonebook screen.

Inbound Phonebook

1. Open the MultiVOIP program.
(Start | MultiVOIP xxx | Configuration
2. Go to Phone Book | PhoneBook Modify | Inbound Phonebook
| Add Entry.
3. In the "Remove Prefix" field, enter your local calling code (area code,
country code, city code, etc.) preceded by any other "access digits"
that are required to reach your local site from the remote voip
location (think of it as though the call were being made through the
PSTN – even though it will not be).
North America,
Long-Distance Example
Seattle-Chicago system.
Seattle is area 206. Chicago
employees must dial 81
before dialing any Seattle
number on the voip system.
Answer: 1206 is prefix to be
Rotterdam/Bordeaux system.
Rotterdam is country code 31, city code 010. Bordeaux
employees must dial 903110 before dialing any
Rotterdam number on the voip system.
Answer: 03110 is prefix to be removed by local
removed by local
(Seattle) voip.
Euro, International Call Example
(Rotterdam) voip.
67
Quick Start Instructions
Euro, National Call
Example
London/Birming. system.
Inner London is 0207 area.
Birmingham employees must
dial 9 before dialing any
London number on the voip
system.
Answer: 0207 is prefix to be
removed by local
(London) voip.