Field Name
Inter Digit
Regeneration
Time
Current Loss
Current Loss
Detect Timer
Tone Detection
FXO Interface: Parameter Definitions (cont'd)
Values
Dialing Options (cont'd)
50 to 20,000
milliseconds
FXO Disconnect On
Y/N
integer values
(in milliseconds )
Y/N
249
Technical Configuration (Analog/BRI)
Description
The length of time between the
outputting of DTMF digits.
Default = 100 ms.
There are three possible criteria
for disconnection under FXO:
current loss, tone detection, and
silence detection.
Disconnection can be triggered
by more than one of the three
criteria.
Disconnection to be triggered
by loss of current. That is,
when Current Loss is enabled
("Y"), the MultiVOIP will hang
up the call when it detects a loss
of current initiated by the
attached device.
The minimum time required for
detecting the current loss signal
on the FXO interface. In other
words, this is the minimum
length of time the current must
be absent to validate 'current
loss' as a disconnection
criterion. Default = 500 ms.
Disconnection to be triggered
by a tone sequence.