Quick Start Instructions
Phone/IP Details *Absolutely Needed*

Gather Telephone Information (E1)

E1 Phone Parameters
Ask phone company or
PBX maintainer.
• Which frame format is used?
• Which CAS or PRI protocol is used? ______________
• Clocking: Does the PBX or telco switch use
• Which line coding is used?
• Pulse shape level?: (most commonly 0 to 40 meters)

Gather Telephone Information (Analog)

Analog Phone Parameters
Ask phone company or
telecom manager.
• Which interface type (or "signaling") is used?
• If FXS, determine whether the line will be used for a
• If FXO, determine if line will be an analog PBX
• If E&M, determine these aspects of the E&M trunk
E1 Telephony Parameters:
Record for this VOIP Site
MultiFrame w/ CRC4 modified
or
clocking? _________________
internal
external
Note that the setting used in the voip unit will be the
opposite of the setting used by the telco/PBX.
Analog Telephony Interface Parameters:
Record for this VOIP Site
_____
E&M
phone, fax, or KTS (key telephone system)
extension or an analog line from a telco central office
line from the PBX:
• What is its Type (1, 2, 3, 4, or 5)?
• Is it 2-wire or 4-wire?
• Is it Dial-Tone or Wink?
MultiVOIP User Guide
Info needed to operate:
MVP3010
Double Frame
MultiFrame w/ CRC4
___ or
AMI
HDB3
Needed for:
MVP810
MVP410
MVP210
MVP130
MVP130FXS
_____
FXS/FXO
48
(cont'd)
_____
_____
_____
___