Operation and Maintenance
E1 Statistics Screen
Field
Name
Red Alarm
Blue Alarm
Loss of
Frame
Alignment
E1 Statistics: Field Definitions
Values
Description
Integer tally of
The alarm condition declared when a
alarms
device receives no signal or cannot
counted since
synchronize to the signal being received. A
last reset.
Red Alarm is generated if the incoming
data stream has no transitions for 176
consecutive pulse positions.
Tally since last
Alarm signal consisting of all 1's (including
reset.
framing bit positions) which indicates
disconnection or failure of attached
equipment.
Tally since last
Loss of data frame synchronization.
reset.