Multitech MULTIVOIP MVP-2410 User Manual page 244

Voice over ip gateways
Hide thumbs Also See for MULTIVOIP MVP-2410:
Table of Contents

Advertisement

Technical Configuration (Analog/BRI)
FXS Loop Start Interface: Parameter Definitions (cont'd)
Field Name
Inter Digit
Timer
Message
Waiting
Indication
Inter Digit
Regeneration
Time
Ring Count,
FXS
FXS Options,
Current Loss
Values
Dialing Options fields
1 - 10 seconds
--
in milliseconds
1-99
Y/N
244
MultiVOIP User Guide
Description
This is the length of time that
the MultiVOIP will wait
between digits. When the time
expires, the MultiVOIP will
look in the outbound
phonebook for the number
entered and place the call
accordingly.
Default = 2.
Not applicable to FXS Loop
Start interface
The length of time between the
outputting of DTMF digits.
Default = 100 ms.
Maximum number of rings that
the MultiVOIP will issue before
giving up the attempted call.
When enabled, the MultiVOIP
will interrupt loop current in
the FXS circuit to initiate a
disconnection. This tells the
device connected to the FXS
port to hang up. The Multi-
VOIP cannot drop the call; the
FXS device must go on hook.

Advertisement

Table of Contents
loading

Table of Contents