MERLIN LEGEND Communications System Release 7.0
System Programming 555-670-111
3
Programming Procedures
Data Features
Table 3-7.
Procedure
Ringing Options
Assign Data Hunt Group
Members
Assign Data Hunt Group
Trunks or Pools
Group Type
Analog Multiline Telephones at Data
Workstations
Use this procedure to dedicate a pair of extension jacks to provide the voice and
data to an analog data workstation.
The extension number associated with the first (odd-numbered) extension jack in
the pair is the telephone's extension number. The extension number for the
second (even-numbered) extension jack is dedicated to Data.
Calls cannot be placed to the extension jack reserved for data.
The Voice Announce feature must be disabled at data workstations.
When you select Enter after entering the voice extension number in the data
entry screen, the system automatically assigns the data extension.
Use the Inspect feature to verify extension pairs.
Summary: Analog Multiline Telephones at Data
Workstations
Programmable by
Mode
Idle Condition
Planning Form
Other Data Programming Procedures — Continued
System Manager
All
System idle
2a, System Numbering: Extension Jacks
4b, Analog Multiline Telephone
5a, Direct-Line Console (DLC): Analog Data
Data Form 2a, Analog Data Workstation
Location
''Ringing Options'' on page 4-37
''Group Calling Member Assignments'' on page
3-415
''Group Calling Line/Trunk or Pool Assignments''
on page 3-419
''Group Type'' on page 3-454
to Automatic Log ln)
3
3
Issue 1
April 1999
3-632
(choice restricted
Need help?
Do you have a question about the MERLIN LEGEND Release 7.0 and is the answer not in the manual?