MERLIN LEGEND Communications System Release 5.0
System Planning 555-650-112
2
Control Unit Configuration
Numbering the System
0
1
100 — 199
2
200 — 299
3
300 — 399
4
400 — 499
5
500 — 599
6
600 — 699
Main Pool
7
70
8
800*
9
* Listed Directory Number (QCC Queue)
** Remote Access
*** System default. Can not be changed.
Figure 2-4.
Extension Numbers for Set Up Space Numbering Plan
Planning Form Instructions
Use Figures
1.
Identify the 2-digit, 3-digit, or Set Up Space numbering system you will be
using under the Factory Set column on Form 2b by circling the name of the
appropriate numbering system.
2.
Do one of the following:
Operator Console
Stations
MFMs / TAs
7100 — 7299
7300 — 7499
Trunks
801 — 880
ARS Access (Hybrid / PBX Mode ) / Idle Line Access
2-2
through
2-4
as you record extension number information:
If you do not need to renumber any of the factory-set extension
numbers:
a.
Check the 2-Digit, the 3-Digit, or the Set Up Space box under
the Renumber System heading on Form 2a to indicate the
numbering plan youre using.
b.
Skip to the next section,
If you want to renumber only a few of the extensions and there are
enough numbers available for 2- and 3-digit numbering plans:
a.
Check the 2-Digit, the 3-Digit, or the Set Up Space box to
indicate the numbering plan youre using. Be sure to check
Selected Extension Numbers under the Renumber System
heading on Form 2a , page 1 .
b.
Write the new extension number(s) in the Renumber to
columns on Form 2a and Form 2b.
0***
Calling Group
770 — 791, 7920 — 7929
Park
881 — 888
9***
''Updating Planning
Issue 1
June 1997
Page 2-30
Page
793 — 799
Pools
889**
890 — 899
Information''.

Advertisement

Table of Contents
loading