Lucent Technologies MERLIN LEGEND Release 5.0 System Planning Manual page 105

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Planning 555-650-112
3
Lines/Trunks
Selecting Line/Trunk Options
7.
Under the Line Compensation heading:
a.
b.
Table 3-3.
Setting
1 (factory setting)
2
3
4
5
*
Based on 22-gauge cable.
8.
If the system includes both 800 NI-BRI and 100D modules, clock
synchronization planning should be completed at the same time. There is
only one primary/secondary/tertiary clock for both 800 NI-BRI modules and
100D modules, with the same system programming screens used for both
types.
Plan your clock source administration to minimize the need for clock
switching, which is known to cause noise on active calls.
Under Priority in the Clock Synchronization section, do one of the following:
Fill in the approximate distance (number of cable feet) between the
100D module and its channel service unit (CSU) or other far-end
connection in the space provided next to Cable Feet.
Use
Table 3-3
to select the Line Compensation setting needed. (The
factory setting is a value of 1.)
Line Compensation Settings
dB Loss
-0.6
-1.2
-1.8
-2.4
-3.0
If installing only one 100D module:
— To keep the factory setting, check Primary (that is, this
module provides synchronization for the system).
— If the synchronization source is other than through the 100D
module, check None.
If installing more than one 100D module, decide which module, if
any, provides the primary synchronization:
— If Module 1 provides clock synchronization, check Primary in
the first box (the factory setting).
— If Module 2 (or Module 3) provides clock synchronization,
check Primary in the box that describes that 100D module.
— If the synchronization source is other than through a 100D
module, check None.
*
Cable Feet
0 133
133 266
266 399
399 533
533 655
Issue 1
June 1997
Page 3-23