MERLIN LEGEND Communications System Release 5.0
System Planning 555-650-112
F
Unit Load Calculation
Continued from previous page
Module
Equipment
MDC 9000
MDW 9000
10-Button Basic
Optional Equipment
10-Button HFAI
34-Button Basic
34-Button DLX
34-Button BIS
34-Button BIS/DIS
Single-Line Telephone
Direct Station Selector
General-Purpose Adapter
Hands-Free Unit
Headset Adapter
† The MFM has its own wall power unit located at the telephone and, therefore, is not added to
the unit load calculation.
‡ Up to two DSSs (one DSS for each MLX-28D or MLX-20L) can be powered from each control
unit carrier. For example, a three-carrier system can have six system operator positions, each
with one DSS powered from the control unit.
9. Try to exchange modules between carriers to reduce the unit loads for slots
5 and 6 through 27. (Remember that the 100D, 800 NI-BRI, 400, 400
GS/LS, 800, and 800 GS/LS modules have unit loads of 0.0.) Repeat Steps
1 through 8 to recalculate unit loads for each new configuration.
NOTES:
Empty slots are not permitted between modules.
Qty x
Total Actual Unit Load
If the unit load for slots 5 and 6 is less than or equal to 27, power is suf-
ficient for the carrier.
If the exchange does not reduce the unit load for slots 5 and 6 to 27, in-
stall wall power units for the appropriate number of telephones to reduce
the unit load to 27.
Unit Load
Hybrid/PBX
or Modified
Key
0.0
0.0
0.0
0.0
0.9
1.1
1.0
1.2
0.9
1.1
1.2
1.7
1.2
1.4
1.2
1.4
0.6
0.7
0.7
0.9
0.8
1.0
0.8
1.0
0.8
1.0
Issue 1
June 1997
Page F-8