Unit Load Calculation
Module
008
008 MLX
008 OPT
012
016
100D
400
400 EM
400 GS/LS/TTR
408
408 GS/LS
408
GS/LS-MLX
800
800 GS/LS
800 DID
800 GS/LS-ID
MERLIN LEGEND Mail
Total Estimated Unit Load
(for the 391A3 power supply), no further calculation is required.
ply) or more, continue to Step 6.
6. Calculate the actual carrier unit load.
Qty x
If total is less than 54 (for the 391A1 or 391A2 power supplies) or 75
If total is 54 (391A1 or 391A2 power supplies) or 75 (391A3 power sup-
If the total actual unit load is less than or equal to 54 (391A1 or 391A2
power supplies) or less than or equal to 75 (391A3 power supply), no fur-
ther calculation is required.
If the total actual unit load is more than 54 (391A1 or 391A2 power sup-
plies) or more than 75 (391A3 power supply), continue to Step 7.
Unit
= Total
Load
12.0
13.25
8.0
8.4
12.8
0.0
0.0
8.0
0.0
12.0
12.0
13.5
0.0
0.0
8.0
8.0
0.0
Issue 1