NI-1 BRI Review
11. Once you have determined your Service Configuration, do one of the follow-
ing:
12. Specify the total number of BRI lines under the Number of BRI Lines Or-
dered heading.
13. If CPN/BN is available with the BRI lines ordered, check the CPN/BN box
under the Additional Features heading.
14. Make a copy of the NI-1 BRI Planner for your records and forward the orig-
inal to the technician who will perform the installation.
The MERLIN LEGEND has currently been tested with each switch type
in the following configurations:
— AT&T 5ESS in a linear hunt group
— Northern Telecom DMS-100 in a circular hunt group
— Siemens SSC EWSD in a circular hunt group
Other configurations are possible, but are not guaranteed to work.
Appendix H, ''NI-1 BRI Provisioning''
tion screens of the Series Completion and MLHG features. These
screens show the fields and parameters for the CO switch and may be
forwarded to the local service provider if necessary.
If your Service Configuration will be IOC "S", check the box beside the
IOC "S" selection under the Service Configuration heading, then enter
the number of BRI lines that will be provisioned using this package.
If your Service Configuration will be MLH, check the box beside the MLH
selection under the Service Configurations heading.
— Indicate the type of MLH configuration by checking the box for
MLHG (Northern Telecom DMS-100) or Series Completion (AT&T
5ESS or Siemens SSC EWSD).
— Enter the total number of BRI lines provisioned using MLH, the
number of BRI lines provisioned as voice only hunt groups, the
number of BRI lines provisioned as data only hunt groups, and the
number of BRI lines provisioned as voice/data hunt groups in the
spaces provided.
NOTE:
MERLIN LEGEND Release 4.0 does not support voice/data hunt
groups with the Siemens SSC EWSD CO switch.
provides sample LEC administra-
Issue 1
June 1997