Bri Connectivity - Lucent Technologies MERLIN LEGEND Release 5.0 System Planning Manual

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Planning 555-650-112
3
Lines/Trunks
Selecting Line/Trunk Options
4.
Under the Signaling heading, do one of the following:
5.
Under the Invalid Destination heading, do one of the following. (The Invalid
Destination setting applies to both blocks. You cannot specify a different
setting for each block.)
6.
Group DID trunks into each block by assigning the DID trunks according to
how incoming calls must be routed to reach the proper extension numbers,
and transfer the information from Form 2c, System Numbering: Line/Trunk
Jacks to the Trunks included in Block section of Form 3d. Write the logical
ID, trunk number, and telephone number in the applicable columns.
7.
Select the disconnect time for each DID trunk by doing one of the following
under the Disconnect Time heading:
If this system is installed outside of the U.S., continue to the next section.
Otherwise, skip to the following section,
NI-1 BRI Connectivity
To ensure proper operation of the BRI line features, the following options must be
set on the MERLIN LEGEND system during system programming:
Service Profile Identifier (SPID) for each BRI line B-channel
Directory Number (DN) for each BRI line B-channel
If the number of digits sent by the local telephone company is more
than the number of digits in the system numbering plan, specify that
one to four digits be deleted from the telephone company digits by
checking the appropriate number (1, 2, 3, or 4) under the Delete
Digits heading.
If the number of digits sent by the local telephone company is fewer
than the number of digits in the system's numbering plan, specify
the specific digits (1 9999) to be added to the digits sent; check the
Add these digits box under the Add Digits heading and then write
the specific digits to be added in the space provided.
To keep the factory-set signal, check Rotary.
To change the setting, check Touch-Tone. (You cannot have
touch-tone if you selected Immediate-Start.)
To indicate that calls to unassigned extension numbers go to the
backup position (usually the primary operator), check Send to
backup position.
To indicate that calls to unassigned extension numbers should
receive a fast busy signal, check Return to fast busy.
To keep the factory setting, check 500 ms.
To change the disconnect time, write the new value (10 to 2550) in
the Other column.
''Assigning
Lines/Trunks''.
3
Issue 1
June 1997
Page 3-39

Advertisement

Table of Contents
loading

Table of Contents