Hardware Installation

You can use the following subsections to install the RocketLinx ES7506:

Connect the Power

Mount the RocketLinx ES7506
Connect the Ethernet Ports
Connect the Alarm Relay Output
Connect the Power
The RocketLinx ES7506 provides redundant power inputs (PW1/2). PW1 and PW2 inputs support reverse polarity protection.
The ES7506 can signal an alarm for loss of power on either PW1 or PW2. If both power inputs are connected, the RocketLinx
ES7506 is powered from the highest connected voltage. Positive and negative power system inputs are both accepted but PW1
and PW2 must apply the same mode.
1.
Connect the DC power inputs.
a.
Insert positive and negative wires (12-24AWG) into the PWR+ and PWR- contacts.
Note: Power should be disconnected from the power supply before
connecting it to the switch. Otherwise, your screwdriver blade can
inadvertently short your terminal connections to the grounded
enclosure.
b.
Tighten the wire-clamp screws to prevent the wires from coming loose.
Electrical Specifications
Power Input Voltage
PWR1/PWR2
PoE Output Voltage
Maximum PoE Power/
Port
Total Power Budget
Hardware Installation
on Page 8
on Page 9
on Page 10RocketLinx ES7506
IEEE 802.3af
Standard
48 (48-57VDC)
Manual
IEEE 802.3af
55 (55-57VDC)
Ultra
Forced 15.4W
48 (48-57VDC)
Forced 30W
55 (55-57VDC)
IEEE 802.3af
Standard
44-57V
Manual
IEEE 802.3af
50-57V
Ultra
Forced
44-57V
IEEE 802.3af
Standard
15.4W
Manual
IEEE 802.3af
Ultra
30W
Forced
Maximum
Up to 100 W
Values
RocketLinx ES7506 User Guide: 2000529 Rev. E - 7