Comtrol ES7506 User Manual page 51

Industrial rack mount managed poe switch; 4 - poe ports 2 - 10/100base-tx ports
Hide thumbs Also See for ES7506:
Table of Contents

Advertisement

Port Status
Switch# show interface fa1
Interface fastethernet1
Administrative Status : Enable
Operating Status : Connected
Duplex : Full
Speed : 100
Flow Control :off
Default Port VLAN ID: 1
Ingress Filtering : Disabled
Acceptable Frame Type : All
Port Status
Port Security : Disabled
Auto Negotiation : Disable
Loopback Mode : None
STP Status: forwarding
Default CoS Value for untagged packets is 0.
Mdix mode is Disable.
Medium mode is Copper.
Note: Administrative Status -> Port state of the port. Operating status -> Current status of the port. Duplex
-> Duplex mode of the port. Speed -> Speed mode of the port. Flow control -> Flow Control status
of the port.
Rate Control
Switch(config-if)# rate-limit
egress
Rate Control –
ingress
Ingress or
Egress
Note: To enable rate control, you should select the Ingress or Egress rule first; then assign the packet type
and bandwidth.
Switch(config-if)# rate-limit ingress mode
all
broadcast
Rate Control –
Filter Packet
flooded-unicast
Type
multicast
Switch(config-if)# rate-limit ingress mode broadcast
Set the ingress limit mode broadcast ok.
Switch(config-if)# rate-limit ingress bandwidth
0
1024
128
2048
Rate Control -
256
Bandwidth
4096
512
8192
Switch(config-if)# rate-limit ingress bandwidth 8192
Set the ingress rate limit to 8192k for Port 1.
Command Lines for Port Configuration
Outgoing packets
Incoming packets
Limit all frames
Limit Broadcast frames
Limit Broadcast, Multicast and flooded unicast frames
Limit Broadcast and Multicast frames
0 is no limit
1024 is 1024Kbps
128 is 128Kbps
2048 is 2048Kbps
256 is 256Kbps
4096 is 4096Kbps
512 is 512Kbps
8192 is 8192Kbps
Command Lines for Port Configuration
RocketLinx ES7506 User Guide: 2000529 Rev. E - 51