Warning

Warning
The RocketLinx ES7506 provides several types of warning features for you to remotely monitor the status of the attached
devices or changes in your network. The features include Fault Relay, System Log and SMTP Email Alert. The following
commands are included in this group:

Fault Relay

Event Selection
on Page 90
SysLog Configuration
SMTP Configuration
CLI Commands for Warnings
Fault Relay
The RocketLinx ES7506 provides one digital output (Relay Output). The
relay contacts are energized (open) for normal operation and close under
fault conditions. Fault conditions include Power Failure, Ethernet Port Link
Failure, Ping Failure, and Ring Topology Change. You can enable and select
relay trigger by clicking the Apply button.
Relay 1: Enable the Relay 1 box, and then select the Event Type and its
parameters.
Event Type: You will be given the following options: Dry Output, Power
Failure, Link Failure, Ping Failure, and Super Ring Failure. Each event type
has its own parameters and is configurable. Each Relay can have one event
type.
Event Type: Dry Output
On Period (Sec): Enter the amount of time you would like the Relay
Output to be on. This can range from 0-4294967295 seconds.
Off Period (Sec): Enter the amount of time you would like the Relay
Output to be off. This can range from 0-4294967295 seconds.
When the amount of time is reached, the RocketLinx ES7506 turns the
Relay Output on or off.
Event Type: Power Failure
Power ID: Select either Power 1 or Power 2. When power is shut down, the
RocketLinx ES7506 will short the Relay Out and the DO LED lights.
88 - RocketLinx ES7506 User Guide: 2000529 Rev. E
on Page 91
on Page 92
on Page 93
Warning