Fault Relay
Event Type: Link Failure
Link: Select the port ID you would like to monitor.
How to configure: Check the box of the Ethernet port or ports you want to
monitor. When the selected ports are unlinked, the system will short the
Relay Output and light the DO LED.
Event Type: Ping Failure
IP Address: Enter the IP address of the target device you want to ping.
Reset Time (Sec): Enter the amount of time after a ping has failed that you
would like the relay output to turn off.
Hold Time (Sec): Enter the amount of time after a ping has failed and relay
output has been turned off, that you would like the relay output to be turned
back on.
How to configure: After selecting the Ping Failure event type, the system
changes the Relay Output to short state, lights the alarm LED, and
continuously pings the target device. When the ping failure for the Reset
Time times out, the system changes the Relay Output to open state and turns
off the alarm LED for the amount of time entered in the Hold Time. After the
Hold Time times out, the RocketLinx ES7506 starts sending ping commands
to the remote device.
Example: When the Reset Time is set to 10 sec while the Hold Time is set to 40 sec the following occurs. After ping has failed
after 10 seconds (Reset Time), the system will turn the Relay Output and Alarm LED off. After 40 seconds (Hold Time), the
system turns the Relay Output and the Alarm LED on again.
Event Type: Super Ring Failure
Select Ring Failure and when the Ring topology changes, the RocketLinx
ES7506 will short the Relay out and light the Alarm LED.
Once you have finished configuring the settings, click the Apply button to
apply your configuration.
Fault Relay
RocketLinx ES7506 User Guide: 2000529 Rev. E - 89