Hardware Installation
You can use the following subsections to install the RocketLinx ES8508 Series:
•
Connect the Power and Ground
•
Connect the Digital Input and Relay Outputs
•
Mount the ES8508
•
Connect the Ethernet Ports
•
Connect the Fiber Port (ES8508F)
•
LED Descriptions
on Page 14
•
Panel Layout
on Page 15
•
Reset Button
on Page 16
Connect the Power and Ground
You can use the following procedure to connect power and the ground to the ES8508.
1. Connect the DC power inputs.
a. Insert positive and negative wires (12-24AWG) into the PW+ and PW- contacts.
Positive and negative power system inputs are both accepted, but
PW1 and PW2 must be in the same mode.
Note: Power should be disconnected from the power supply before connecting it to the switch.
Otherwise, your screw driver blade can inadvertently short your terminal connections to the
grounded enclosure.
RocketLinx ES8508 Series User Guide: 2000575 Rev. A
on Page 11
on Page 12
on Page 13
12 - 24AWG Wire
12 - 24AWG Wire
on Page 10
Power Supply
10 - 60VDC
(UL Listed)
V+
V-
Wiring Positive Power Supplies
Power Supply
10 - 60VDC
(UL Listed)
V+
V-
AC Power Input
AC Power Input
Hardware Installation - 9