no logging buffered wrap
This command disables wrapping of in-memory logging and configures logging to stop when the
log file capacity is full.
Format
no logging buffered wrap
Mode
Privileged EXEC

logging cli-command

This command enables the CLI command logging feature, which enables the 7000 series software
to log all CLI commands issued on the system.
Default
enabled
Format
logging cli-command
Mode
Global Config
no logging cli-command
This command disables the CLI command Logging feature.
Format
no logging cli-command
Mode
Global Config

logging console

This command enables logging to the console. You can specify the <severitylevel> value as
either an integer from 0 to 7 or symbolically through one of the following keywords: emergency
(0), alert (1), critical (2), error (3), warning (4), notice (5), info (6), or debug
(7).
Default
disabled; critical when enabled
Format
logging console [severitylevel]
Mode
Global Config