RMON Commands

rmon alarm

Sets alarm conditions.
Synopsis
rmon alarm index snmp_oid interval seconds {absolute | delta} rising-threshold value event
number [falling-threshold value event number [owner name] | owner name]
no rmon alarm index [snmp_oid interval seconds {absolute | delta} rising-threshold value event
number [falling-threshold value event number [owner name] | owner name]]
Operands
index
snmp_oid
interval seconds
absolute
delta
Defaults
There are no alarms configured.
Command
Global configuration mode
Modes
Description
Use this command to set alarm conditions. Use the no rmon alarm command to disable the alarm
conditions.
Usage
There are no usage guidelines for this command.
Guidelines
Examples
To set alarm conditions:
Dell Converged Enhanced Ethernet Command Reference
53-1002115-01
Specifies the alarm index. The range of valid values is 1-65535.
Specifies the MIB object to monitor. The variable must be in the SNMP OID
format, for example, 1.3.6.1.2.1.16.1.1.1.5.65535. The object type must be a
counter32.
Specifies the alarm sample interval in seconds. The range of valid values is
1-2147483648.
Sets the sample type as absolute.
Sets the sample type as delta.
rising-threshold value
Specifies the alarm rising threshold. The range of valid values is
0-4294967295.
event number
Specifies the event for the rising alarm. The range of valid values is 1-65535.
falling-threshold value
Specifies the alarm falling threshold. The range of valid values is
0-4294967295.
event number
Specifies the event for the rising alarm. The range of valid values is 1-65535.
owner name
Specifies the identity of the owner. The maximum number of characters is 32.