Configuring the Management Port Physical Parameters

Setting the IP Address and Subnet Mask of the Management Interface

The user must define the IP address of the management interface.
When both management ports are connected, providing a redundant management port, this IP address
always acts as a virtual IP address for the currently active management port, regardless of which port is
the active port.

Options

The following options are available:
From the SCE(config if)# prompt, type ip address ip-address subnet-mask and press Enter.
Step 1
The command might fail if there is a routing table entry that is not part of the new subnet defined by the
new IP address and subnet mask.
Changing the IP address of the management interface via telnet will result in loss of the telnet connection
Note
and inability to reconnect with the interface.
After changing the IP address, you must reload the SCE platform so that the change will take effect
Note
properly in all internal and external components of the SCE platform. (See
Down the SCE Platform, page

Setting the IP Address and Subnet Mask of the Management Interface: Example

The following example shows how to set the IP address of the SCE platform to 10.1.1.1 and the subnet
mask to 255.255.0.0.
SCE(config if)#ip address 10.1.1.1 255.255.0.0
Cisco SCE 2000 and SCE 1000 Software Configuration Guide
5-4
Options, page 5-4
Setting the IP Address and Subnet Mask of the Management Interface: Example, page 5-4
IP address — The IP address of the management interface.
If both management ports are connected, so that a backup management link is available, this IP
address will be act as a virtual IP address for the currently active management port, regardless of
which physical port is currently active.
subnet mask — subnet mask of the management interface.
Chapter 5