How To Configure The Duplex Operation Of The Management Interface; Specifying The Active Management Port - Cisco SCE2020-4XGBE-SM Configuration Manual

Software configuration guide
Table of Contents

Advertisement

Configuring the Management Port Physical Parameters
Configuring the Speed of the Management Interface: Example
The following example shows how to use this command to configure the Management port to 100 Mbps
speed.
SCE(config if)#speed 100

How to Configure the Duplex Operation of the Management Interface

Options
The following options are available:
If the speed parameter is configured to auto, changing the duplex parameter has no effect (see ).
From the SCE(config if)# prompt, type duplex auto|full|half and press Enter.
Step 1
Specify the desired duplex option.
Configuring the Duplex Operation of the Management Interface: Example
The following example shows how to use this command to configure a management port to half duplex
mode.
SCE(config if)#duplex half

Specifying the Active Management Port

This command explicitly specifies which management port is currently active. Its use varies slightly,
depending on whether the management interface is configured as a redundant interface (auto fail-over
enabled) or not (auto fail-over disabled).
This command is a Privileged Exec command, unlike the other commands in this section, which are Mng
Note
Interface Configuration commands. If in Mng interface configuration mode, you must exit to the
privileged exec mode and see the SCE# prompt displayed.
Cisco SCE 2000 and SCE 1000 Software Configuration Guide
5-6
Options, page 5-6
Configuring the Duplex Operation of the Management Interface: Example, page 5-6
duplex — duplex operation of the currently selected management port (0/1 or 0/2):
full
half
auto (default) — auto-negotiation (do not force duplex on the link)
Options, page 5-7
Specifying the Active Management Port: Example, page 5-7
auto fail-over enabled (automatic mode) — the specified port becomes the currently active port, in
effect forcing a fail-over action even if a failure has not occurred.
auto fail-over disabled (manual mode) — the specified port should correspond to the cabled Mng
port, which is the only functional port and therefore must be and remain the active management port.