Monitoring the Operational Status of the SCE Platform
Monitoring the Operational Status of the SCE Platform
•
•
Table 3-1
platform via:
•
•
Table 3-1
SCE platform
Operational Status Description
Booting
Operational
Warning
Failure
Cisco SCE 2000 and SCE 1000 Software Configuration Guide
3-12
How to Display the Current Operational Status of the SCE Platform, page 3-13
Displaying the Current Operational Status of the SCE Platform: Example, page 3-13
the operational states of the SCE platform. You can monitor the operational status of the SCE
The Status LED on the SCE platform front panel
The show system operation-status CLI command
SCE Platform Operational States
Initial state after reset
SCE platform becomes operational after completing the
following process:
Boot is completed
•
Power self-tests are completed without failure
•
Platform configuration is applied
•
SCE platform is fully operational (as above) but one of the
following occurred:
Link on one of the line ports is down
•
Management port link is down
•
Temperature raised above threshold
•
Voltage not in required range
•
Fans problem
•
Power supply problem
•
•
Insufficient space on the disk
Note: If the condition that caused the SCE platform to be in
Warning state is resolved (for example, link is up) the SCE
platform reverts to Operational state.
System is in Failure state after Boot due to one of the following
conditions:
•
Power on test failure
•
Three abnormal reboots in less than 20 minutes
•
Platform configured to enter Failure mode consequent to
failure-induced reboot (this is configurable using CLI
command)
Note: Depending on the cause of failure, the management
interface and the platform configuration may or may not be
active/available.
Chapter 3
Operations
Status LED
State
Orange
Flashing green
Flashing orange
Red
OL-7827-12