Setting Delay Time
Delay time is set to ignore measurements immediately after the timing input. This is
useful for avoiding bounding during device startup and the influence of machine
vibration.
The delay time (the delay between timing input and the start of sampling) and the
sampling period can be set.
The default delay time setting is [OFF].
Make the sum of the delay time and sampling period less than the timing input ON interval.
If the next timing input for measurement is received before the delay and sampling period have
passed, that timing input will be ignored and will not be reflected in the sampling.
Timing input
Moving to Delay Hold (H-DLY)
1.
Use the LEFT and RIGHT Keys to display
[H-DLY] on the main display.
[H-DLY] will not be displayed if the delay conditions are
set to [OFF].
2.
Press the UP or DOWN Key.
The sub-display will flash.
3.
Use the UP and DOWN Keys to display [ON].
4.
Press the ENT Key.
The settings mode for the H-DLY function is now
enabled.
Delay time
Sampling period
ON
OFF
Ignored
Section 5
DETAILED SETTINGS
Delay time
Accepted
LD ON
ZERO
ENABLE
SUB
SUB
SUB
ZX-L-N