Omron L User Manual page 113

Smart sensors laser type
Table of Contents

Advertisement

Section 5
DETAILED SETTINGS
This section describes how to set the output range, using an example of current output
with a range with the following conversions: 35mm to 4 mA and 45mm to 20 mA.
Change the values in this example for voltage output as necessary.
Output current
(mA)
20
4
0
1.
Turn OFF the power supply to the Amplifier Unit.
2.
Move the current/voltage switch to current
output. The switch is found on the bottom of
the Amplifier Unit.
The default setting is voltage output.
Moving to FUN Mode and SPCL
3.
Turn ON the power supply and move the
mode switch to FUN.
4.
Use the LEFT and RIGHT Keys to display
[SPCL] on the main display.
Moving to FOCUS
5.
Press the UP or DOWN Key.
The sub-display will flash.
6.
Use the UP and DOWN Keys to display [SET]
or [ALL].
7.
Press the ENT Key.
ZX-L-N
96
User's Manual
Measured value
(mm)
20
Output current
(mA)
20
4
0
35
45
Voltage output
Current output
LD ON
SUB
SUB
SUB
Measured value
(mm)
ZERO
ENABLE
(mm)

Advertisement