Omron L User Manual page 119

Smart sensors laser type
Table of Contents

Advertisement

Section 5
DETAILED SETTINGS
Output Settings for Non-measurement
The linear output method for when a reset is input can be set.
Selection
KEEP (Default)
CLAMP
• For Hold Measurements
• Even in FUN mode, the outputs will be made according to the non-measurement settings.
Moving to FUN Mode and SPCL
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT Keys to display
[SPCL] on the main display.
Moving to RESET
3.
Press the UP or DOWN Key.
The sub-display will flash.
4.
Use the UP and DOWN Keys to display
[ETC] or [ALL].
5.
Press the ENT Key.
6.
Use the LEFT and RIGHT Keys to display
[RESET] on the main display.
ZX-L-N
102
User's Manual
Judgement outputs
The status immediately before measurement is stopped is held and output.
All OFF.
Even if [KEEP] is set, the output before the first hold value is obtained will be the same as
CLAMP.
Outputs
Linear output
Outputs the set CLAMP value.
The following options are available.
• For current output: 3 to 21mA or maximum
(approx. 23mA)
• For voltage output: -5 to 5V or maximum
(approx. 5.5V)
SUB
SUB
SUB
LD ON
ZERO
ENABLE
(mm)
LD ON
ZERO
ENABLE
(mm)