Functions
Measured value display
Present value display
Output value display
Set value display
Light amount display
Resolution display
Scaling
Display reverse
Indicator OFF mode
ECO Mode
Display digit change
Sample hold
Indicators
Judgement indicators: HIGH (orange), PASS (green), LOW (yellow), 7-segment main display
(red), 7-segment sub-display (yellow), Laser ON (green), zero reset (green), enable (green)
Power supply
12 to 24 VDC ±10%, Ripple (p-p) 10% max.
voltage
Power
3.4 W max. (Sensor connected) (Power supply voltage: 24 V, Current consumption: 140 mA max.)
consumption
Ambient
Operating and storage: 0 to 50°C (with no icing or condensation)
temperature
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Insulation
20 MΩ (at 500 VDC)
resistance
Dialectic strength
1,000 VAC, 50/60 Hz for 1 min
Vibration
10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions
resistance
(destructive)
Shock resistance
300 m/s
(destructive)
Connection
Prewired (standard cable length: 2 m)
method
Weight (packed
Approx. 350 g
state)
Materials
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories
Instruction sheet
(*1) The response speed of the linear output is calculated as the measurement period x (No. of samples to average
setting + 1).
The response speed of the judgement outputs is calculated as the measurement period x (No. of samples to
average setting + 1).
(*2) Current/voltage can be switched using the switch provided on the bottom of the Amplifier Unit.
(*3) Setting is possible via the monitor focus function.
(*4) A Calculating Unit is required.
(*5) Intensity mode can be used with Reflective type sensor head only.
(*6) Auto scale can be used with Through-beam type sensor head only.
ZX-LDA11-N
Peak hold
Bottom hold
Peak-to-peak hold
Self-up trigger
Self-down trigger
Average hold
Delay hold
Delay time setting
Previous value
comparison
Intensity mode (*5)
Auto scale(*6)
Zero reset
Initial reset
ON-delay timer
3 times each in six directions (up/down, left/right, forward/backward)
2
ZX-LDA41-N
OFF-delay timer
Non-measurement
One-shot timer
settings
Differentiation
(A-B) calculations (*4)
Sensitivity selection
(A+B) calculations (*4)
Direct threshold value
Thickness calculation
setting
Position teaching
(*4)
Two-point teaching
Mutual interference
Automatic teaching
(*4)
Hysteresis width change
Laser deterioration
Monitor focus
detection
Lock function
Zero reset memory
Section 7
APPENDIX
ZX-L-N
133
User's Manual