Comparing Measured Values (Previous Value
Comparisons)
Use the previous value comparison function to ignore gradual changes in measured values
over time, due to factors such as temperature drift, and only detect and judge sudden
changes.
The hold function must be set before previous value comparison can be set. The difference
from the previous hold value with a PASS judgement becomes the measured value.
For example, if the judgement for that previous measurement is HIGH or LOW, the
comparison is performed with the hold value before that.
Measured value
(After comparison
with previous value)
PASS
HIGH
The hysteresis width setting will be disabled if the previous value comparison function is used.
Hysteresis Setting p.94
Moving to FUN Mode and SPCL
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT Keys to display
[SPCL] on the main display.
ZX-L-N
86
User's Manual
Hold value
X(n)-X(n-1)
ON
OFF
ON
OFF
Sudden change
Gradual change
X(n)
X(n-1)
HIGH threshold
LD ON
ZERO
ENABLE
(mm)