Section 5
DETAILED SETTINGS
Automatic Teaching
When automatic teaching is executed, measurement is performed continuously while
the keys are held down, and the maximum and minimum measurements during that
period are set as the threshold values.
Automatic teaching is useful when you want to set threshold values by starting the
device and obtaining real measurements.
Hold, trigger mode, and scaling settings that have been made before teaching are reflected in the
teaching measurements.
Moving to T Mode
1.
Set the mode switch to T.
2.
Start the device.
The threshold switch can be set to either position. Both HIGH and LOW thresholds will be set,
regardless of the switch setting.
ZX-L-N
92
User's Manual
Sensor head
Maximum
value
Sensing
object
Minimum
value
Minimum value = LOW threshold
Maximum value = HIGH threshold
Moved