Omron L User Manual page 41

Smart sensors laser type
Table of Contents

Advertisement

Section 2
PREPARATION FOR MEASUREMENT
Calculating Units
When you want to perform calculations between Amplifier Units, prevent mutual
interference between Sensor Heads or connect ZX-SF11 to perform communication
between Amplifier Units, use a Calculating Unit to connect the Amplifier Units.
The number of Amplifier Units that can be joined depends on the functions being used.
Functions
Calculation
Mutual interference
prevention
Communication (when
ZX-SF11 is used)
Provide power to all connected Amplifier Units.
Connection Method
1.
Open the connector cover on the Amplifier Unit.
Open the connector cover by lifting and sliding it open.
2.
Mount the Calculating Unit to the DIN Track.
3.
Slide and connect the Calculating Unit to the Amplifier Unit connector.
4.
Slide and connect the second Amplifier Unit to the Calculating Unit connector.
To disconnect the Interface Unit, perform the above operations in reverse order.
ZX-L-N
24
User's Manual
No. of Connectable Amplifier Units
Max. 8
Max. 2
Max. 5
2
3
1
4
1