Omron L User Manual page 77

Smart sensors laser type
Table of Contents

Advertisement

Section 4
MAIN APPLICATIONS AND SETTING METHODS
Measuring Deflection
Use the peak-to-peak hold function to measure the normal deflection.
Rotate the motor shaft, input a timing signal from an external device, and measure the
deflection.
The difference between the maximum and minimum measurement results (the
deflection) will be used as a reference when setting tolerances.
Refer to Section 5 Detailed Settings for details on settings.
Using Hold Functions p.76
Setting Tolerance Judgement Values
Refer to the deflection measured in step
threshold) or lower limit (LOW threshold) for a PASS (OK) judgement.
The judgement result will be output based on the threshold value set here. The output
will depend on the type of threshold set.
Output when upper limit is set: PASS or HIGH
Output when lower limit is set: PASS or LOW
Measurement Result
Measurement result > HIGH threshold
LOW threshold ≤ Measurement result ≤ HIGH threshold
LOW threshold > Measurement result
Refer to Section 5 Detailed Settings for details on operation.
Inputting Threshold Values Directly p.89
ZX-L-N
60
User's Manual
v
Measured value
Deflection
Timing input
t
and set either the upper limit (HIGH
Judgement
HIGH
PASS
LOW

Advertisement

Table of Contents
loading

This manual is also suitable for:

ZxZx-l-n series

Table of Contents