DETAILED SETTINGS

Hysteresis Setting

Set the hysteresis width for the upper and lower limits of judgements if the HIGH,
PASS, or LOW judgement is unstable near the threshold values.
HIGH threshold
Measured value
LOW threshold
HIGH
Output
PASS
LOW
Hysteresis width settings are disabled when previous value comparison is used.
To prevent self-trigger chattering, set hysteresis for the self-trigger.
Moving to FUN Mode and HYS
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT Keys to display
[HYS] on the main display.
3.
Press the UP or DOWN Key.
The leftmost digit of the sub-display will flash.
4.
Use the Cursor Keys to enter the hysteresis
width.
5.
Press the ENT Key to confirm the setting.
The setting will be registered.
Countermeasures for Setting Errors
If [ERROV] is displayed, [HIGH threshold – LOW
threshold] is smaller than the hysteresis width.
If an error is displayed, the threshold values have not
been updated.
Set the values again or change the threshold values.