Omron L User Manual page 114

Smart sensors laser type
Table of Contents

Advertisement

8.
Use the LEFT and RIGHT Keys to display
FOCUS on the main display.
Selecting Current (mA) or Voltage (V) Output
9.
Press the UP or DOWN Key.
The sub-display will flash.
10.
Display [mA].
Always select the same output as the current/voltage switch selection on the bottom of the Amplifier
Unit.
Setting the First Point (A)
11.
Press the ENT Key.
The display will change to the settings for the first point
(A).
The output current will be displayed on the main display.
The measured value will be displayed on the sub-display
and the leftmost digit will flash.
12.
Set the output current value and the
corresponding measured value for the first
point.
Set a measured value within the measurement distance.
If scaling or calculation has been set, set a value that
reflects those settings.
The flashing digit, i.e., the digit for which a value can be set, will change as shown in the diagram.
Digit shift on sub-display
Switching from the sub-display to the
main display and vice versa
(From the leftmost/rightmost digit of the
sub-display)
LD ON
ZERO
ENABLE
(mm)
Shifts one
digit at a
time.
SUB
LD ON
ZERO
SUB
Section 5
DETAILED SETTINGS
LD ON
ZERO
SUB
LD ON
ZERO
SUB
Moves from one digit to
another.
Changes the current value.
LD ON
ZERO
ENABLE
(mm)
SUB
ENABLE
(mm)
ENABLE
(mm)
ENABLE
(mm)
ZX-L-N
97
User's Manual