Setting Judgement Output Timing (Timer) - Omron L User Manual

Smart sensors laser type
Table of Contents

Advertisement

Section 5
DETAILED SETTINGS

Setting Judgement Output Timing (Timer)

The timing for judgement outputs can be adjusted to match the operation of external devices.
Selection
OFF
(Default)
OFF-D
(OFF-delay
timer)
ON-D
(ON-delay timer)
1-Sht
(One-shot timer)
ZX-L-N
104
User's Manual
Outputs the judgement as soon as the
judgement result has been confirmed.
After the measurement result has
been confirmed, delays turning OFF
the PASS output for the timer time.
Also delays turning ON the HIGH and
LOW outputs for the timer time.
After the measurement result has
been confirmed, delays turning ON
the PASS output for the timer time.
Also delays turning OFF the HIGH and
LOW outputs for the timer time.
When the measured value changes
from HIGH to PASS or from LOW to
PASS, turns ON the PASS output with
a pulse width equivalent to the timer
time.
Neither the HIGH nor the LOW output
are output.
Details
Measured value
HIGH threshold
LOW threshold
HIGH output
ON
OFF
PASS output
ON
OFF
LOW output
ON
OFF
Measured value
HIGH threshold
LOW threshold
ON
HIGH output
OFF
ON
PASS output
OFF
ON
LOW output
OFF
Measured value
HIGH threshold
LOW threshold
HIGH output
ON
OFF
PASS output
ON
OFF
LOW output
ON
OFF
Measured value
HIGH threshold
LOW threshold
HIGH output
ON
OFF
ON
PASS output
OFF
ON
LOW output
OFF
: Delay time
: Delay time
: Delay time

Advertisement

Table of Contents
loading

This manual is also suitable for:

ZxZx-l-n series

Table of Contents