Section 4
MAIN APPLICATIONS AND SETTING METHODS
Mounting to Device
Mount the Sensor Head to the inspection device.
When mounting the sensor, take care not to exert pressure on the sensor head and
wires.
Installing Sensor Heads p.18
Setting Auto Scale
Decide whether to display the received light amount in mm or in % in the Amplifier
Unit's main display.
Setting the Auto Scale p.42
Example: To display 5mm as the current input light amount (85%)
Setting the Standard Received Light Amount
With 100% laser input from the emitter to the receiver, set the standard received light
amount.
When the standard received light amount is set, the main display and linear outputs
(current, voltage) will be set to the full scale (F.S.) automatically.
Setting the Standard Received Light Amount p.45
Example: Setting the standard received light amount after setting auto scale to
ZX-L-N
62
User's Manual
Before auto scale is set
LD ON
ZERO
ENABLE
(mm)
2
[5-L] in step
Before the standard received light
amount is set
LD ON
ZERO
ENABLE
(mm)
Auto scale is set to [5-L].
LD ON
ZERO
ENABLE
Since 100% is equivalent to 5.000mm,
[4.250] will be displayed in the case of 85%.
After the standard received light
amount is set
LD ON
ZERO
ENABLE
The current input light amount (85%) will be set to
the full scale (F.S.) and [5.000] will be displayed.
(mm)
(mm)