Configure Trigger, Exposure, And Line Rate Settings; Control Via External Triggers; Control Without External Triggers - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)

Configure Trigger, Exposure, and Line Rate Settings

This section describes how to control the exposure time with or without external triggers.
Note: For the details on the short ASCII commands required to configure the Trigger,
Exposure and Line Rate settings, see

Control via External Triggers

When Controlling the Exposure Time Using Specified Exposure Times
1. Set Exposure Mode to Timed. (Timed = Default).
2. Specify the Exposure Time in Exposure Time.
3. Set Trigger Mode to On.
4. Configure the Trigger Source and Trigger Activation settings if necessary.
When Controlling the Exposure Time Using the Pulse Width of the Trigger Input
Signal
1. Set Trigger Mode to On.
2. Set Exposure Mode to TriggerWidth. When ExposureMode is set to TriggerWidth,
TriggerMode is automatically set to On.
3. Configure the Trigger Source and Trigger Activation settings if necessary.

Control Without External Triggers

When Controlling the Exposure Time Using Specified Exposure Times
1. Set Exposure Mode to Timed. (Timed = Default).
2. Set Trigger Mode to Off. (Off = Default)
3. Specify a line period slower than the exposure time in Acquisition Line Rate.
When Not Controlling the Exposure Time
1. Set Exposure Mode to Off. (Off =Default)
The exposure will be performed with an exposure time equal to 1 / line rate.
Note: The exposure time specified in ExposureTime will be disabled.
"Acquisition
Control".
- 25 -