ExposureMode = TriggerWidth
Mode in which control of the exposure time is performed using the pulse width of the trigger input
signal. The exposure time will be the same as the pulse width of the trigger input signal.
Notes:
The settings for exposure control and triggers are related to each other. Be sure to configure
l
the settings described in
When exposed to strong light, the accumulation time may appear to shift due to PLS
l
(Parasitic Light Sensitivity) and other effects.

Actual Exposure Time

Related Setting Items:
When ExposureMode is set to Timed, the actual exposure time will consist of the image sensor's
offset duration (2.45us) added to the ExposureTime setting configured on the camera.
Actual Exposure Time: ExposureTime value (us) + 2.45us
Note: On this camera, the ExposureActive signal's pulse width includes the Exposure offset
duration (2.45us). Therefore, "ExposureActive signal's pulse width = ExposureTime value (us) +
2.45(us)."

RCT Mode

Related Setting Items:
In RCT mode, the image is not output from the camera until FrameStartTrigger is input, but internally
the imaging operation is continued and the automatic gain control (AGC) function, the automatic
shutter control (ASC) function and the automatic white balance (AWB) function can be continued.
You can use RCT mode when:
ExposureMode is set to Timed, and FrameStartTriger is set to On.
l
Sequencer Function
l
AcqusutionMode = Continuous
l
Trigger
Control.
AcquisitionControl
AcquisitionControl
= Off