Installing The Server In The Rack; Other Important Information - Fujitsu PRIMERGY RX2540 M7 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Important information
3.2.9

Installing the server in the rack

CAUTION
For safety reasons, at least 2 people are required to install the
server in the rack because of its weight and size.
(For Japan, see "安全上のご注意".)
Never lift the server into the rack using the Quick Release Levers
(QRLs) on the front panel.
When connecting and disconnecting cables, observe the relevant
instructions in the "Important Information" chapter of the technical
manual for the corresponding rack. The technical manual is
supplied with the corresponding rack.
When installing the rack, ensure that the anti-tilt mechanism is
correctly fitted.
Do not extend more than one server out of the rack simultaneously
even if the tilt protection is in place. If several servers are
simultaneously extended from the rack, there is a risk that the rack
could tip over. See the safety information of the rack and the
warning label.
If the server/rack is intended for permanent connection to the mains
only an authorized specialist (electrician) is allowed to work. Please
follow the regulation of each country.
If the server is integrated into an installation that draws power from
an industrial power supply network with an IEC309 type connector,
the power supply's fuse protection must comply with the
requirements for non-industrial power supply networks for the type
A connector.
3.2.10

Other important information

▶ During cleaning, observe the instructions in the corresponding operating
manual chapter "Operation" > "Cleaning the server".
▶ Keep all manuals close to the server. All documentation must be included if
the equipment is passed on to a third party.
42
Upgrade and Maintenance Manual
RX2540 M7

Advertisement

Table of Contents
loading

Table of Contents