Fujitsu PRIMERGY RX2540 M7 Upgrade And Maintenance Manual page 97

Table of Contents

Advertisement

In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL), see
Event Log (SEL)" on page
When using the Infrastructure Manager, please refer to the following
manuals about backup and restore function of system information.
See manual "FUJITSU Software Infrastructure Manager V2.8.0 User's
Guide", section "2.10 Backup/Restore Hardware Settings", available at:
https://ts.fujitsu.com/support/
For Japan:
See manual "FUJITSU Software Infrastructure Manager V2.8.0 解説書",
section "2.10 ハードウェア設定バックアップ/リストア機能", available at:
https://www.fujitsu.com/jp/products/software/infrastructure-software/
infrastructure-software/serverviewism/technical/
After replacing the system board
▶ Check the SEL log files to verify whether the backup data on the Chassis ID
EPROM has been restored to the system board, see
the System Event Log (SEL)" on page
Chassis IDPROM: Motherboard Exchange detected
Chassis IDPROM: BMC FW restore successful
Chassis IDPROM: BIOS restore successful
If the restore failed, manually reconfigure the BIOS/iRMC configuration
information.
If a Remote Management Controller upgrade license has been installed, it
must be reconfigured.
For more information, see the "iRMC S6 - Web Interface" user guide.
After replacing the front panel or Chassis ID EPROM
▶ Check the SEL log files to verify whether a backup copy of the system board
settings has been transferred to the Chassis ID EPROM, see
clearing the System Event Log (SEL)" on page
Chassis IDPROM: BMC FW backup successful
RX2540 M7
"Viewing and clearing the System
105.
105.
Upgrade and Maintenance Manual
Basic software procedures
"Viewing and clearing
"Viewing and
105.
97