Fujitsu PRIMERGY RX2540 M7 Upgrade And Maintenance Manual page 535

Table of Contents

Advertisement

LEDs A, B and C are visible from outside on the server rear. All other
LEDs are only visible if the server cover has been opened.
If the server has been powered off (power plugs must be disconnected) it is
possible to indicate the faulty component by pressing the indicate CSS button.
A - Identification
Status
blue on
flashing blue
B - CSS (Customer Self Service)
Status
off
orange on
flashing orange
C - GEL (Global Error LED)
Status
off
orange on
RX2540 M7
Description
The server has been highlighted using iRMC S6 web
interface or the ID button on the front panel for easy
identification.
The server has been highlighted for easy
identification using the iRMC S6 (AVR) with disabled
local VGA output.
Description
No critical event detected (CSS component).
Prefailure event detected (CSS component).
CSS component failure detected.
Description
No critical event detected (non-CSS component).
Prefailure event detected (non-CSS component).
Upgrade and Maintenance Manual
Appendix A
535