Fujitsu PRIMERGY RX2540 M7 Upgrade And Maintenance Manual page 162

Table of Contents

Advertisement

Hard disk drive (HDD) / solid state disk (SSD)
▶ Release all HDD modules and pull them out a few centimeters, see
"Removing 3.5-inch HDD modules" on page
CAUTION
The HDD modules need not to be removed.
If you want to remove them nevertheless, check if all HDD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶ Release all dummy modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD dummy module" on page
Removing the defective 12x 3.5-inch HDD backplane
▶ If applicable, remove the SAS expander board holder, see
SAS expander board holder" on page
▶ Remove the internal RAID riser module, see
riser module" on page
▶ Disconnect all cables from the HDD backplane.
Figure 70: Removing the 12x 3.5-inch HDD backplane
▶ Release the nine screws (see circles).
▶ Take out the HDD backplane at a slight angle.
162
208.
303.
Upgrade and Maintenance Manual
153.
151.
"Removing the
"Removing an internal RAID
RX2540 M7

Advertisement

Table of Contents
loading

Table of Contents